PORTABLE DIMMER PACKS |
APOLLO PLUS 625C |
APOLLO PLUS 350C |
APOLLO PLUS 363C |
CHANNELS |
6 |
3 |
3 |
CHANNEL CAPACITY |
5750W |
11500W |
14490W |
MAXIMUM CURRENT / CHANNEL |
25A |
50A |
63A |
LOAD TYPES |
-Incandescent lamps -Iron core transformer for low-voltage incandescent lamps -Resistive & inductive loads |
HARD-FIRED TRIACS |
YES |
- |
- |
OUTPUT FILTER |
100μs (optional 200μs) |
200μs |
200μs |
OUTPUT LED MONITORS |
YES |
YES |
YES |
HARD-FIRED THYRISTORS |
- |
YES |
YES |
CIRCUIT BREAKERS |
YES |
YES |
YES |
ANALOGUE INPUTS |
0/+10VDC |
20VDC OUTPUT FOR EXTERNAL CONTROL DESK |
YES |
YES |
YES |
BUILD-IN SLIDERS+ MASTER |
YES |
YES |
YES |
DMX 512 INPUT |
YES |
YES |
YES |
INDICATION OF DMX “ FAULT” STATUS |
YES |
YES |
YES |
PROGRAMMABLE START ADDRESS |
YES |
YES |
YES |
DMX-512 SIGNAL BUFFER |
YES |
YES |
YES |
TERMINATION SWITCH |
YES |
YES |
YES |
HOLDING OF LAST DMX VALUE |
YES |
YES |
YES |
PROGRAMMABLE BEHAVIOR ON DMX SIGNAL INTERRUPTION |
YES |
YES |
YES |
5-DIGIT NUMERIC DISPLAY |
YES |
YES |
YES |
4-BUTTON KEYPAD, 2 OF WHICH CAN BE PROGRAMMED BY THE USER AS FUNCTION KEYS |
YES |
YES |
YES |
MENU DRIVEN SOFTWARE |
YES |
YES |
YES |
PASSWORD FOR SETTINGS PROTECTION |
YES |
YES |
YES |
LAWS |
LINEAR, HALOGEN, AND FLUORESCENT |
SELECTABLE SWITCHED OUTPUT |
YES |
YES |
YES |
PROGRAMMABLE PREHEAT LEVEL PER CHANNEL |
YES |
YES |
YES |
PROGRAMMABLE PERCENTAGE OF OUTPUT VOLTAGE PER CHANNEL |
YES |
YES |
YES |
PROGRAMMABLE SOFT TURN-ON PER CHANNEL |
YES |
YES |
YES |
CHANNEL LEVEL CONTROL |
Sliders |
Sliders |
Sliders |
24 PROGRAMMABLE MEMORIES |
YES |
YES |
YES |
12 PROGRAMMABLE CHASERS |
YES |
YES |
YES |
12 FACTORY- SET CHASERS |
YES |
YES |
YES |
60- STEP LOOP FUNCTION |
YES |
YES |
YES |
MEMORY OR CHASE ASSIGNMENT OF SLIDERS |
YES |
YES |
YES |
DIAGNOSTIC TESTS |
YES |
YES |
YES |
WATCHDOG TIMER |
YES |
YES |
YES |
DC SPEED CONTROLLED, FAN ASSISTED CONVECTION COOLING |
YES |
YES |
YES |
HIGH TEMPERATURE DETECTION |
YES |
YES |
YES |
AUTO POWER HANDLING AT HIGH TEMPERATURE CONDITION |
YES |
YES |
YES |
POWER FAILURE AND POWER OFF MODES ON LOW POWER SUPPLY VOLTAGE |
YES |
YES |
YES |
DISABLED OUTPUT ON POWER SUPPLY OVERVOLTAGE |
YES |
YES |
YES |
RACK MOUNTING |
YES |
YES |
YES |
WALL MOUNTING |
- |
- |
- |
TRUSS MOUNTING |
YES |
YES |
YES |
HEAVY DUTY HANDLE |
YES |
YES |
YES |
230V 400V-3/N/PE/50Hz,3 PHASE STAR CON/TION. |
YES |
YES |
YES |
230V 3/PE/50Hz,3 PHASE DELTA CONNECTION |
Optional |
Optional |
Optional |
DIMENSIONS (WxHxD) IN MM |
432 x 222 x 400 |